Classical solid phase microextraction spme fiber compared with intube. Solid phase microextraction terpenes and testing magazine. Solid phase microextraction for quantitative analysis in. Solid phase microextraction spme, is a solid phase extraction technique that involves the use of a fiber coated with an extracting phase, that can be a liquid or a solid, which extracts different kinds of analytes including both volatile and nonvolatile from different kinds of media, that can be in liquid or. Solidphase microextraction an overview sciencedirect topics. Advantages and disadvantages of solid phase extraction. Recent developments and applications of solid phase. It is rapid and simple, which makes it ideal for automation and in situ measurements, and no harmful solvents are used.
Thirty years since the invention and public disclosure of solid phase microextraction spme, the technology continues evolving and inspiring several other green extraction technologies amenable. Pdf solid phase microextraction techniques used for gas. An explanation of proven methods of chemical analysis, focusing on the myriad applications of solid phase microextraction spme to laboratories performing highsample throughput, quick sample turnaround time, low detection levels, and dirty sample matrices. Application of solidphase microextraction in analytical. Dec 31, 2014 microextraction microextraction is defined as an extraction technique where the volume of the extracting phase is very small and extraction of analytes is not exhaustive. It can concentrate volatile and nonvolatile compounds in liquids or gaseous samples, for subsequent analysis by gc or hplc. Over this time period the solid phases or sorbent materials used for extractions have been engineered into many different types and formats to solve specific or generic sample preparation problems in a wide variety of applications. Solidphase microextraction spme is a solventfree sample preparation. Microextraction is relatively newer area which provides some unique features. Headspacesolid phase microextraction fast gc in combination with principal component analysis as a tool to classify different chemotypes of chamomile flowerheads matricaria recutita l. Solid phase microextraction spme has undergone a surge in popularity within the field of analytical chemistry in the past two decades since its introduction.
Solid phase microextraction spme sample preparation. Sample preparation using solid phase extraction spe has been in use for several decades. Solid phase microextraction, developed by pawliszyn kevin et al. Pdf applications of liquidphase microextraction in the. Jul 06, 2018 chromatography online reports that solid phase microextraction provided results comparable to a conventional solvent extraction procedure. Application of headspace solidphase microextraction gas. Simplified solid phase extraction spe with stratax. The fiber is then removed and desorbed in the inlet of the gc or gcms.
Solid phase microextraction solid phase microextraction spme is a widely applied technique, being a solventfree method which exploits the high adsorption power of a fused silica fibre coated with a specific extraction phase, which is selected according to the type of matrix. Pdf comparison of solidphase microextraction and stir. Comparison of solid phase microextraction and stir bar sorptive extraction for the quantification of malodors in wastewater. Spe and spme were followed by gas chromatographymass spectrometry gc ms. Solid phase microextraction 235 on gasliquid or liquidliquid partitioning. The advantages of automated systems compared to manual. Solidphase extraction spe, solidphase microextraction spme, gas. As an analytical scientist, you are faced with many challenges when determining what tools you can best use to achieve the desired result. Solidphase microextraction chromatography online home page. Principles of spme anca tugulea, university of waterloo, canada level basic. Comparison for challenging cases author links open overlay panel ezel boyac. Spme is a green technology because it eliminates organic solvents from analytical laboratory and can be used in environmental, food and fragrance, and forensic and drug analysis.
Liquidliquid extraction lle or solidphase extraction spe are the most commonly used extraction techniques for preconcentration of cps from aqueous samples, although solidphase microextraction spme using gas chromatography with electron capture detection has also been recently reported. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. The relatively new technique of solid phase microextraction spme is an important tool to prepare samples both in the lab and onsite. The present study reports the development of a simple and sensitive cold fiber solid phase microextraction sampling method for the determination of acrolein in exhaled air and indoor air by gas. Information and translations of solidphase microextraction in the most comprehensive dictionary definitions resource on the web. Apr 24, 2012 spme solid phase microextraction is a solventless extraction technique, used to remove and preconcentrate low levels of volatile and semivolatile organic compounds from soil, water and air. Sep 26, 2016 sample extraction is the most popular sample preparation method in an analytical method. Solid phase microextraction spme was developed to address the need for a fast, solventfree and field compatible sample preparation method.
In spme, coated fibers are used to isolate and concentrate analytes into a range of coating. In most cases only a small fraction of the initial analyte is extracted for analysis. Solid phase microextraction spme was invented in 1990 by dr. Optimisation of headspace solid phase microextraction hsspme conditions the effect of each tested parameter by means of the 2 3 full factorial design was reported in the form of a pareto chart in fig. The most widely used technique of sampling with solid phase microextraction consists of exposing a small amount of extracting phase coating associated with a fibre to the sample, for a predetermined amount of time. Meiratliff at western connecticut state university. Solid phase microextraction, or spme, is a solid phase extraction sampling technique that involves the use of a fiber coated with an extracting phase, that can be a liquid or a solid, which extracts different kinds of analytes including both volatile and nonvolatile from different kinds of media, that can be in liquid or gas phase. Solid phase microextraction was developed to address the need for rapid sample preparation. May 31, 2017 basic principles of solid phase microextraction spme method development spme allows the simultaneous extraction and enrichment of analytes of interest from a given matrix in a single step while avoiding, or drastically minimizing, the use of organic solvents and timeconsuming cleanup procedures. A solid phase extraction consists of bringing a liquid or gaseous test sample in contact with a solid phase, whereby the analyte is selectively adsorbed on the surface of the solid phase other solvents liquids or gasesadded to remove possible adsorbed matrix components eluting. Solid phase microextraction spme with a splitsplitless. This technique does not require the use of solvents, therefore it is suitable for preparing samples.
Solid phase microextraction is a fast, solventless alternative to conventional sample extraction techniques. Solid phase microextraction spme is a convenient and efficient extraction method that involves using a thin polymer film coating on a fine silica fiber to adsorb analytes of interests from a sample matrix. Microextraction solid phase microextraction liquid phase microextraction 5 6. The socalled intube or inneedle extraction techniques. Solidphase microextraction an overview sciencedirect. Solid phase microextraction spme is a very simple and efficient, solventless sample preparation method, invented by pawliszyn in 1989. The purpose of creating this technique was to address the need for a fast, solventfree, and field compatible sample preparation method. Spme videos solid phase microextraction sigmaaldrich. Sample preparation with solid phase microextraction and.
Solidphase extraction versus solidphase microextraction. Solidphase micro extraction spme uses a polymercoated fiber to extract and concentrate vocs and svocs from the headspace above a sample, or from an aqueousphase sample. Spme is routinely applied to gasphase and liquidphase extraction, and spe is limited to extraction. Some of them are discussed below so let us check it out one by one. It has been applied to a range of applications including environmental, industrial hygiene, process monitoring, clinical, forensic, food and drug analysis. Solidphase microextraction 235 on gasliquid or liquidliquid partitioning.
Development, optimization and applications of thin film solid. Jan 23, 2019 use of solid phase microextraction spme for cell culture metabolomic analysis allows for the attainment of more sophisticated data from in vitro cell cultures. Comparison of solidphase extraction and solidphase. Solid phase microextraction an overview sciencedirect topics.
Solidphase microextraction spme is a technique for the extraction of organic compounds from gaseous, aqueous and solid matrices such as many environmental samples. However, the former technique offered several advantages compared to the latter, including fewer handson steps, no organic solvent, less consumables, and a sample injection into the gc gas. Handbook of solid phase microextraction 1st edition. Automated solid phase microextraction spme into a gas chromatograph with a mass spectrometer detector is shown using the gerstel multipurpose sampler mps. Sample treatmentpreparation procedures using octadecylsilane as common phase for solid phase extraction spe and solid phase microextraction spme were compared for the analysis of the pesticides pyrimethanil, kresoximmethyl and tebufenpyrad in water samples. Sample preparation with solid phase microextraction and exhaustive extraction approaches. Aug 25, 2011 defination of solid phase extraction spe. Solid phase extraction video with sample prep scientists joni stevens and ben yong of agilent technologies 2011 the most important fundamentals of spe sample preparation are. Comparison of the sensitivity of static headspace gc, solid. Solid phase microextraction and related techniques for drugs. Recent developments in solid phase microextraction techniques. Pdf solidphase microextraction spme and its application to.
Solid phase microextraction spme is a unique sample preparation technique that eliminates most of the drawbacks of extracting organics, requiring no solvents or complicated apparatus. Solid phase microextraction an overview sciencedirect. In this study, solid phase micro extraction in which extraction and analysis are accomplished using a single device, is compared to microliquidliquid extractionlarge volume injection mllelvi, in which a liquidliquid extraction is performed within a sample vial and the organic phase is. Direct thermal desorption tds, sometimes referred to as dynamic headspace analysis, and solid phase microextraction spme are alternative techni. Definition of solidphase microextraction in the dictionary.
A tutorial demonstrating the solid phase extraction techniques utilized in the laboratory of dr. Theoretical and practical comparison of solid phase micro. Simplified solid phase extraction spe with stratax youtube. A theoretical model is proposed to deal with the dynamic adsorption process of spme. Fritless solidphase extraction cartridges duration. Headspace solid phase microextraction hspme is a technique which is used to prepare samples. Headspace solid phase microextraction spme and gas chromatographymass spectrometry gcms was used to identify 84 vocs, including many that are toxic, e. Janusz pawliszyn and colleagues from the university of waterloo in canada. Fritless solid phase extraction cartridges duration. Solid phase extraction solidphase extraction spe is a sample preparation method where the compounds that are dissolved or suspended in a liquid mixture are separated from other compounds depending on their physical and chemical properties. Solid phase microextraction spme, developed by pawliszyn and coworkers in 1990, is a new sample preparation technique using a fusedsilica fibre that is coated on the outside with an appropriate stationary phase. The use of solid phase microextraction for metabolomic. Sample extraction is the most popular sample preparation method in an analytical method. A simple sample extraction process pierce sample expose fiber retract pierce gc inlet expose fiber gc hplc retract fiber insert fiber into desorb fiber add mobile retract mobile to hplc column the extraction of organic compounds from a sample matrix usually consists of purgeandtrap or headspace methods for.
In spme, analytes establish equilibria among the sample matrix, the headspace above the sample, and a polymercoated fused fiber, then are desorbed from the fiber to a chromatography column. Use of solid phase microextraction spme for cell culture metabolomic analysis allows for the attainment of more sophisticated data from in vitro cell cultures. Through the development of solid phase microextraction spme. Solidphase microextraction spme is a miniaturized and solventfree sample preparation technique for chromatographicspectrometric analysis by which the analytes are extracted from a gaseous or liquid sample by absorption in, or adsorption on, a thin polymer coating fixed to the solid surface of a fiber, inside an injection needle or inside a capillary. Headspace solidphase microextraction analytical chemistry. Basic principles of solid phase microextraction spme method. Solid phase microextraction spme is a widely applied technique, being a solventfree method which exploits the high adsorption power of a fused silica fibre coated with a specific extraction phase, which is selected according to the type of matrix. Static headspace gc hsgc is probably the most commonly applied technique for analysis of volatiles in solids. Sample preparation is an essential step in analysis, greatly influencing the reliability and accuracy of resulted the time and cost of analysis. Jan 29, 2014 simplified solid phase extraction spe with stratax.
567 990 441 195 1409 636 1482 357 1305 556 762 785 1190 1277 217 1438 1462 408 1381 869 1388 467 23 1193 16 862 1238 714 352 880 1358 479 215 201 1292 1256 682 500 1410